P.E. Beam & Auto-Close
Step 22 - Fitting the P.E. Beams (optional)
Affix the P.E. Beams (PE-2) in a strategic location
within the doorway. We recommend 150mm above
the floor level and as close as possible to the door
opening, inside the garage.
Connect the PE-2 (Order Code 90214) and the
P.E.Beam Interface Kit V2 (Order Code 01901) to
the Opener in accordance with (Fig.38).
Make sure to align the beams correctly. Follow the
manual supplied with the P.E. Beams.
WARNING: When using Auto Close Mode and P.E.
beams, the doorway must be clear of all obstructions
and persons at all times. The location of the beams
and the manner in which it is installed might not
give safety protection at all times. Check to make
sure that the height of the beam and type used
give maximum protection possible.
Step 23 - Setting Up Auto-close Mode
IMPORTANT NOTICE: It is compulsory to have P.E.
Beams installed when using Auto-close mode.
Auto-close mode is a function that automatically closes
the door a preset time after the P.E. Beams recognise
that a vehicle has left the garage.
The Auto-close timer only starts after the P.E. Beam's
path is broken the Auto-close timer has been set. If
the P.E. path is not broken the door will remain open
until the path is broken. If the opener incurs a physical
obstruction (i.e. not from the P.E. Beams) while closing
the door will re-open and not Auto-close until the P.E.
Beam's path is broken again.
Step 23.1 - Setting Auto-close Time
Hold down the AUTO CLOSE TIME button (Fig.39).
While holding in the AUTO CLOSE TIME button,
press the OPEN button - each press will add one
second to the Auto-close delay.
To decrease the delay time follow Step 15.1(a)
and press the CLOSE button - each press will
deduct one second from the Auto-close delay.
Press the OPERATE button or transmitter to open
the door. When the door is fully opened the
OPEN LIMIT LED will flash to indicate that Auto-
close mode is operational.
Break the P.E. Beam's path momentarily to
initialise Auto-close. When the door reaches the
fully opened position, the door will pause for the
set Auto-close time and then close.
a.
b.
a.
b.
c.
d.
e.
38
fig
39
fig
24V
12V
1
2
3
4
5
24V
12V
1 2
3 4 5
R
R
R
R1
B
R
B
B
Y
Y
PWR
PE
PE-
CABLE 1
CABLE 2
RECEIVER
TRANSMITTER
J2
WIRE COLOUR: R-Red, B-Black, Y-Yellow
NOTE: Resistor R1 shall be 2.2kOhm, 1/4W
Model: PE-2 with harness
WARNING: The P.E.Beams will be active only after
the Opener has moved the door through a
completed open or close cycle.